Appearance
Can't connect to a base station
The symptom
A base station's row in Setup, Base stations, shows a red message where it should read "Connected". Or the dashboard shows a banner naming the base station, and its tiles have stopped updating.
Read the exact message first. Each one points at a different cause.
| The row says | Start at |
|---|---|
| "Can't reach" and the address | Check 1 |
| "Login rejected" | Check 2 |
| "SPUNK refused this address" | Check 3 |
| "SPUNK isn't responding." | Check 4 |
| "Not connected: SPUNK runs up to 4 base stations" | Check 5 |
| "In standby." | Check 6 |
The checks
1. Is the address right, and is the base station on the network?
"Can't reach" means the SPUNK server asked and got no answer from that address.
- Compare the IP address in SPUNK with the one on the base station. A base station's address can change between shows.
- On the SPUNK server, open Spectera WebUI in a browser, at
https://<the base station's IP address>/specterawebui/. Expect a security warning, because the base station's certificate is unknown to the browser. If WebUI opens, the SPUNK server can reach the base station and the address is right. - If WebUI doesn't open from the SPUNK server, try it from another computer on the network. This tells you whether the fault is the base station or the SPUNK server's own network connection.
The base station is reached from the SPUNK server, not from the screen in front of you. A screen that can open WebUI proves nothing about the SPUNK server.
2. Is the password right?
"Login rejected" means the base station answered and refused the login.
- Type the device password again, the one set in Spectera WebUI or LinkDesk. It may have been changed since the last show.
- Press Test.
- Open Username on the row and check it reads
controlSennheiser.
A base station blocks a computer for a while after repeated failed logins. SPUNK stops asking as soon as a login is rejected, to avoid this, and starts again when Test succeeds. If you're sure the password is right and the login is still rejected, wait and press Test again.
3. Is it a local network address?
The SPUNK server only passes requests on to 10.x, 172.16 to 172.31, 192.168.x and 169.254.x addresses. It refuses any other. Put the base station on one of those ranges, or correct a mistyped address.
4. Is the SPUNK server still running?
"SPUNK isn't responding." means this screen got no answer from the SPUNK server itself, so the base station isn't the problem yet.
- Do the other screens still update? If none do, check the SPUNK server is switched on and nginx is running.
- If only this screen is stuck, check it is still on the show network, then reload it.
5. Are there more than 4 base stations?
One SPUNK server runs up to 4 base stations. A fifth in the list is never connected. Remove or hide one you don't need.
6. Is the base station in standby?
In standby the base station still answers SPUNK, every pack reads offline and every antenna reads unconnected. SPUNK can't wake it. A base station with every antenna unplugged reads exactly the same, so check the antenna cables as well.
If it connected and then stopped
- Did every pack go offline at once? That points at standby or the antennas. See check 6.
- Did the banner say the login was rejected? Someone changed the device password. See check 2.
- Is WebUI or LinkDesk open on many computers? A base station limits how many connections it accepts at once. Close the ones you don't need.
What to collect if it isn't fixed
- The exact message on the base station's row, and any banner on the dashboard. A screenshot of Setup, Base stations covers both.
- The line under the status: the base station's model, firmware version and serial number, if it has ever connected.
- Whether WebUI opens from a browser on the SPUNK server.
- The SPUNK version, from the bottom of Setup.
- The time it stopped, and what changed just before: a network change, a firmware update, a new password.